To remotely control an external HA, press the rack in which the external HA you want to
control is mounted. The EXTERNAL HA popup window will appear. Here you can remotely
control the external HA by using the knobs and buttons in the M7CLʼs display or the encoders of
the top panel.
1. +48V MASTER- If an external HA is connected to the REMOTE connector, the on/off status of
the master phantom power is shown here. (Switching this on/off is performed on the external HA
itself.)
2. +48V buttons- These switch phantom power on/off for each channel.
3. GAIN knobs- These indicate the gain of the external HA. To adjust the value, press the knob
to select it, and use multi- function encoders 1–8. The level meter located at the immediate right
of the knob indicates the input level for the corresponding port. (Aphex preamps do not provide
level information back to the console. So this meter will not function. However the main input
meters will show the input level from the digital inputs.)
4. FREQUENCY knobs / HPF buttons- These controls switch the external HAʼs built-in high-
pass filter on/off, and adjust its cutoff frequency. If you press the FREQUENCY knob to select it,
youʼll be able to adjust it using the corresponding multifunction encoder. (HPF frequency cannot
be changed!)
5. Rack select tabs- These tabs switch the rack that is displayed in the EXTERNAL HA popup
window.